GONGDA ZHONGJIE GONGDA ZHONGJIE
Industries

POME: what a wide-channel tubular UF can and cannot do

POME is the liquid discharge from palm oil extraction — hot, acidic, oily and colloidal, with most of its organic load in solution. That combination is what fouls a fine-channel membrane, and it is why channel width, not pore size, is the first decision on this stream.

Wide-channel tubular UF elements
Wide-channel tubular UF elements The element type is common across duties. Channel size, element length and cleaning regime are set per stream — nothing on this page is POME-specific except the channel width.

Four properties decide the outcome

Oil that emulsifies

Free oil floats and can be skimmed off. Emulsified oil does not, and it is the single most common reason a membrane fouls in a mill. Whether the oil in a given POME is emulsified depends on the fruit, the mill and what happens upstream.

Solids that are not just silt

POME carries fibre, grit and shell fragments as well as biological solids. Coarse material is exactly what an open channel tolerates and a narrow one does not.

Temperature

It leaves the mill hot. Elements have a temperature rating, so either the stream is cooled before the membrane or the element is specified against the real inlet temperature — measured at the membrane, not at the mill outlet.

Acidity

POME is acidic. That matters twice: for the wetted materials, and for whether an acid clean is available when the membrane eventually fouls.

What a membrane does not do on this stream

Ultrafiltration separates on size. The dissolved organic load that drives BOD and COD passes straight through it. If the target is BOD or COD, that is the biological stage's job and a membrane only polishes what comes out of it. We would rather say this at the start than have it discovered at commissioning.

Where a tubular UF earns its place in a mill

1 · Polishing after the biological stage

When the limit being missed is on suspended solids or oil rather than on BOD, a membrane downstream of the pond or the tank is often the shortest route back to compliance.

2 · Ahead of reverse osmosis

Where the mill wants reuse rather than discharge, the RO stage needs solids and oil taken out first. This is the application we know best — RO pre-treatment is most of what our reference installations do.

3 · Concentrating a sidestream

Where the value is in recovering oil or in cutting the volume going to the pond, the membrane is a concentrator rather than a polisher. Different duty, different sizing, different cleaning regime.

What it does not do

Replace the anaerobic stage. A membrane generates no biogas and removes no dissolved organics. A mill with no biological treatment does not need a membrane first — it needs the biology, and then possibly a membrane.

Why channel width comes before pore size here

The element range covers five open channel diameters. On an oily, fibrous stream the choice between them decides whether the plant runs or plugs.

ChannelWhen it is the right choice
6 mmThe cleanest streams, where packing density matters more than solids tolerance. Not the choice where fibre and grit are present.
8 / 10 mmThe common middle. Most polishing duties land here, and it is where we would start on a POME stream.
12.7 mmWhere the solids or oil load is above what the middle range tolerates.
25 mmFor streams that plug anything smaller. The widest channel we make; it belongs in the specification, not in the headline.
6 – 25 mmOpen channel diameters
30 – 200 nmFiltration rating
pH 0 – 14Wetted materials, acid clean compatible

What "mechanically cleanable" means in a mill

Cleaning is done by pushing sponge balls through the channel, not by backwashing alone. On an oily stream that is the difference between a clean that works and one that merely redistributes the oil over the membrane surface.

Three numbers decide whether it works — none is on a datasheet

Ask these of the mill before anything is sized:

  • Oil content, and specifically whether it is emulsified
  • Peak suspended solids, including fibre and grit
  • Temperature at the point the membrane would sit
  • What the existing biological stage already achieves on BOD and COD — that sets what the membrane still has to do

These four are why we do not publish a design flux for POME. A number that is right for one mill is wrong for the next one.

How a first POME project would run

We will be straight about where we stand. Our operating references are in landfill leachate, RO pre-treatment, plant extraction and chemical effluent — not in a palm oil mill. What we have is the element, the channel range, and a bench test that answers the question in two weeks rather than two years.

1 · Bench test

5–20 L of POME, chilled or preserved. We run it across the candidate channel at your operating temperature and report a flux curve, a cleaning trial, and a plain answer on whether the element is the right tool.

2 · Pilot at the mill

The skid ships to site and is plumbed into the stream, and runs until the cleaning interval repeats — typically four to eight weeks.

3 · Sizing

Element count, tank volumes and chemical consumption come out of the pilot numbers, not out of a catalogue.

If the bench test says the membrane is the wrong tool for your stream, we say so before you spend money on a pilot.

Send a POME sample

The bench test is the cheapest part of the project and the only part that turns these four questions into numbers. Tell us the mill, the flow and what you are trying to meet.

Sample and pilot testing

Common questions

Can a membrane replace the anaerobic pond?

No. Ultrafiltration does not generate biogas and does not remove dissolved organics. It polishes what the biological stage produces; it does not stand in for it.

Will ultrafiltration bring POME down to the discharge limit?

Not on its own. BOD is largely dissolved, and ultrafiltration separates on size. Where the limit being missed is on suspended solids or oil, a membrane helps directly. Where it is on BOD, the biological stage has to carry it.

How do we deal with the temperature?

Measure it where the membrane would sit, not at the mill outlet. If it is above the element rating, either cool the stream or tell us the real number and the element is specified against it.

What if the oil turns out to be emulsified?

That is the case where a membrane is most likely to be the wrong answer, or to need de-emulsification upstream first. It is also the first thing a bench test shows, which is why the test comes before the pilot.

More on this: Selection guide · Tubular UF · Pilot testing